固件

MXA310 - Microflex Advance Table Array Microphone (Dante Only)

所有版本

发布日期

下载

6.0.23
2024年2月29日

Improvements

  • Enhancements to support Designer 6.0.0
  • Additional hardware support

Known Issues

  • An 802.1X re-authorization request interrupts a firmware update and causes it to fail
    • Workaround: restarting the update will resolve the problem
  • AES67 support is only available on UltimoX hardware
    • MXA310 devices manufactured as of July 2017 are compatible with AES67
  • In AES67 mode - Audio does not pass after changing Dante Device name, followed by a reboot
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • The Mute Control Function command string response is incorrect when using <GET 0 ALL>
    • When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
    • When using < GET 0 ALL >, the response should be mapped as follows:
< GET 0 ALL > ResponseActual MUTE_CONTROL_FUNC
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC >LOCAL
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL >LOGIC
< REP MUTE_BUTTON OFF >DISABLED

 

Notes

  • User Guide
  • Command Strings
  • To operate this version of MXA310 with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (Mac OS X)
  • Updating all devices used together to the same firmware version is recommended.
  • To operate this version of MXA310 with Shure software or other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 6.0.0
    • ANI22/ANI4IN/ANI4OUT 6.0.41
    • ANIUSB 6.0.44
    • MXA710 6.0.24
    • MXA910 6.0.24
    • MXA920 6.0.38
    • MXA901 6.0.39
    • MXA902 6.0.32
    • MXN5-C 6.0.17
    • MXA-MUTE 6.0.25
    • MXW 10.0.X
    • P300 6.0.38
    • SCM820 1.4.3
    • Shure Update Utility 2.8.4
    • Shure Web Device Discovery 1.2.17
4.7.8
2022年6月1日

Improvements

  • Bug fixes

Known Issues

  • AES67 support is only available on UltimoX hardware
  • MXA310 devices manufactured as of July 2017 are compatible with AES67
  • In AES67 mode - Audio does not pass after changing Dante Device name, followed by a reboot
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Shure Audio Encryption is not backward compatible; all devices must be on version 4.1 or later firmware to use this feature
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)
  • After updating from version 2.X to 4.2, Channel EQ settings return to their default settings.
  • The Mute Control Function command string response is incorrect when using <GET 0 ALL>
    • When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
    • When using < GET 0 ALL >, the response should be mapped as follows:
< GET 0 ALL > ResponseActual MUTE_CONTROL_FUNC
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC >LOCAL
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL >LOGIC
< REP MUTE_BUTTON OFF >DISABLED

Notes

  • User Guide
  • Demo Web UI
  • Command Strings
  • To operate this version of MXA310 with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (Mac OS X)
  • Updating all devices used together to the same firmware version is recommended.
  • To operate this version of MXA310 with Shure software or other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 4.7.0
    • SystemOn 4.7.0
    • ANI22/ANI4IN/ANI4OUT 4.7.6
    • ANIUSB-MATRIX 4.7.16
    • MXA710 1.5.13
    • MXA910 4.7.13
    • MXN5-C 1.5.12
    • MXA-MUTE 1.5.15
    • Microflex Wireless 10.0.6
    • P300 4.7.11
    • SCM820 1.4.3
    • Shure Update Utility 2.7.1
    • Shure Web Device Discovery 1.2.17
4.6.3
2021年11月5日

Improvements

  • Bug fixes

Known Issues

  • AES67 support is only available on UltimoX hardware
  • MXA310 devices manufactured as of July 2017 are compatible with AES67
  • In AES67 mode - Audio does not pass after changing Dante Device name, followed by reboot
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 or later firmware to use this feature
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)
  • After updating from version 2.X to 4.2, Channel EQ settings return to their default settings.
  • The Mute Control Function command string response is incorrect when using <GET 0 ALL>
    • When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
    • When using < GET 0 ALL >, the response should be mapped as follows:
< GET 0 ALL > ResponseActual MUTE_CONTROL_FUNC
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC >LOCAL
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL >LOGIC
< REP MUTE_BUTTON OFF >DISABLED

Notes

  • User Guide
  • Demo Web UI
  • Command Strings
  • This version of MXA310 is compatible with MXA310 devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
  • To operate this version of MXA310 with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (Mac OS X)
  • To operate this version of MXA310 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
    • Designer 4.6.0
    • SystemOn 4.6.0
    • ANI22/ANI4IN/ANI4OUT 4.6.6
    • ANIUSB-MATRIX 4.6.7
    • MXA910 4.6.6
    • MXA710 1.4.2
    • MXN5-C 1.4.3
    • MXA-MUTE 1.4.4
    • Microflex Wireless 9.0.4
    • P300 4.6.6
    • SCM820 1.4.3
    • Shure Update Utility 2.6.1
    • Shure Web Device Discovery 1.2.17
4.5.8
2021年9月15日

New Features 

  • Services – ability to configure network services

Improvements 

  • Bug fixes

Known Issues 

  • AES67 support is only available on UltimoX hardware
    • MXA310 devices manufactured as of July 2017 are compatible with AES67
  • In AES67 mode - Audio does not pass after changing Dante Device name, followed by reboot
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 or later firmware to use this feature
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)
  • After updating from version 2.X to 4.2, Channel EQ settings return to their default settings.
  • The Mute Control Function command string response is incorrect when using <GET 0 ALL>
    • When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
    • When using < GET 0 ALL >, the response should be mapped as follows:
< GET 0 ALL > ResponseActual MUTE_CONTROL_FUNC
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC > LOCAL
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL > LOGIC
< REP MUTE_BUTTON OFF > DISABLED

Notes 

  • User Guide
  • Demo Web UI
  • Command Strings
  • MXA310 version 4.5.8 is compatible with MXA310 devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA310 version 4.5.8 with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 4.5.8 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
    • Designer 4.5.0
    • SystemOn 4.5.0
    • ANI22/ANI4IN/ANI4OUT 4.5.22
    • ANIUSB-MATRIX 4.5.23
    • MXA910 4.5.8
    • MXA710 1.3.9
    • MXN5-C 1.3.8
    • MXA-MUTE 1.3.28
    • Microflex Wireless 9.0.4
    • P300 4.5.13
    • SCM820 1.4.3
    • Shure Update Utility 2.6.1
    • Shure Web Device Discovery 1.2.9
4.4.9
2021年2月23日

New Feature

  • Call Status support – Changes LED state to notify the user when the room is in a call (off hook) or out of a call (on hook). This feature requires connection to a P300, IntelliMix Room, or an ANIUSB with Logic and Call status enabled.
    • Default setting
      • On hook microphone LEDs off
      • Off hook microphone LEDs on

Improvement

  • Bug Fixes

Known Issues

  • Factory reset occasionally fails to reset Dante settings and/or fully disable encryption. Solution: Reboot the device if unable to route audio after factory reset.
  • AES67 support is only available on UltimoX hardware
    • MXA310 devices manufactured as of July 2017 are compatible with AES67
  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 or later firmware to use this feature
  • If enrolling, unenrolling, or changing Dante Domain settings and selecting “Clear Config,” the device may mute its audio output indefinitely.  Solution: Reboot the device following this operation to avoid possible adverse behavior.”
  • After updating from version 2.X to 4.2, Channel EQ settings return to their default settings.
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).
  • The Mute Control Function command string response is incorrect when using <GET 0 ALL>
    • When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
    • When using < GET 0 ALL >, the response should be mapped as follows:
< GET 0 ALL > ResponseActual MUTE_CONTROL_FUNC
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC >LOCAL
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL >LOGIC
< REP MUTE_BUTTON OFF >DISABLED

Notes

  • User Guide
  • Demo Web UI
  • Command Strings
  • MXA310 version 4.4.9 is compatible with MXA310 devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA310 version 4.4.9 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 4.4.9 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 4.4.0
    • Shure SystemOn 4.4.0
    • ANI22 4.4.8
    • ANI4IN 4.4.8
    • ANI4OUT 4.4.8
    • ANIUSB-MATRIX 4.4.14
    • MXA910 4.3.11
    • MXA710 1.2.1
    • MXA-MUTE 1.2.4
    • MXN5-C 1.2.1
    • Microflex Wireless 8.0.3
    • P300 IntelliMix® Audio Conferencing Processor 4.4.13
    • SCM820 1.3.3
    • Shure Update Utility 2.5.1
    • Shure Web Device Discovery 1.2.9
4.3.6
2020年11月23日

Improvement

  • Bug Fixes

Known Issues

  • Factory reset occasionally fails to reset Dante settings and/or fully disable encryption. Solution: Reboot the device if unable to route audio after factory reset.
  • AES67 support is only available on UltimoX hardware
    • MXA310 devices manufactured as of July 2017 are compatible with AES67
  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 or later firmware to use this feature
  • If enrolling, unenrolling, or changing Dante Domain settings and selecting “Clear Config,” the device may mute its audio output indefinitely.  Solution: Reboot the device following this operation to avoid possible adverse behavior.”
  • After updating from version 2.X to 4.2, Channel EQ settings return to their default settings.
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).
  • The Mute Control Function command string response is incorrect when using <GET 0 ALL>
    • When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
    • When using < GET 0 ALL >, the response should be mapped as follows:
< GET 0 ALL > ResponseActual MUTE_CONTROL_FUNC
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC >LOCAL
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL >LOGIC
< REP MUTE_BUTTON OFF >DISABLED

Notes

  • User Guide
  • Demo Web UI
  • Command Strings
  • MXA310 version 4.3.X is compatible with MXA310 devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA310 version 4.3.X with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 4.3.X with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 4.3.0
    • Shure SystemOn 4.3.0
    • ANI22 4.3.7
    • ANI4IN 4.3.7
    • ANI4OUT 4.3.7
    • ANIUSB-MATRIX 4.3.11
    • MXA910 4.3.2
    • MXA710 1.1.5
    • MXA-MUTE 1.1.3
    • MXN5-C 1.1.1
    • Microflex Wireless 8.0.3
    • P300 IntelliMix® Audio Conferencing Processor 4.3.7
    • SCM820 1.3.3
    • Shure Update Utility 2.5.0
    • Shure Web Device Discovery 1.2.9
4.2.18
2020年7月22日

New Features

  • Compatibility with Shure Designer 4.2

Improvements

  • Bug Fixes

Known Issues

  • Factory reset occasionally fails to reset Dante settings and/or fully disable encryption. Solution:Reboot the device if unable to route audio after factory reset.
  • AES67 support is only available on UltimoX hardware
  • MXA310 devices manufactured as of July 2017 are compatible with AES67
  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 or later firmware to use this feature
  • If enrolling, unenrolling, or changing Dante Domain settings and selecting “Clear Config,” the device may mute its audio output indefinitely.  Solution: Reboot the device following this operation to avoid possible adverse behavior.”
  • After updating from version 2.X to 4.2, Channel EQ settings return to their default settings.
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.2 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).
  • The Mute Control Function command string response is incorrect when using <GET 0 ALL>
  • When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
  • When using < GET 0 ALL >, the response should be mapped as follows:
< GET 0 ALL > ResponseActual MUTE_CONTROL_FUNC
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC >LOCAL
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL >LOGIC
< REP MUTE_BUTTON OFF >DISABLED

Notes

  • User Guide
  • Demo Web UI
  • Command Strings
  • MXA310 version 4.2.18 is compatible with MXA310 devices running version 4.2.18 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA310 version 4.2.18 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 4.2.18 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 4.2
    • Shure SystemOn 4.2
    • ANI22 4.2.18
    • ANI4IN 4.2.18
    • ANI4OUT 4.2.18
    • ANIUSB-MATRIX 4.2.19
    • MXA910 4.2.18
    • MXA710 1.0.5
    • MXA-MUTE 1.0.8
    • MXN5-C 1.0.6
    • Microflex Wireless 8.0.3
    • P300 IntelliMix® Audio Conferencing Processor 4.2.4
    • SCM820 1.3.3
    • Shure Update Utility 2.4.8
    • Shure Web Device Discovery 1.2.9
4.1.37
2020年2月11日

新功能

  • 支持 Dante Domain Manager
  • 支持 Dante Device Lock
  • 支持 AES67

改进

  • 为增强安全性,首次访问用户界面时将提示用户设置密码。用户可以选择不设置密码继续运行,让舒尔Designer配置软件在某一位置内能够安全地配置设备。
    • 密码长度必须至少8个字符,最多64个字符,所有字符均可接受
    • 首次登录后可禁用密码
    • 降级警告:
      • 升级4.1.37版本后,设备的新密码(和/或其音频加密密码)可能超过其先前固件版本允许的长度。在这种情况下降级,需要执行以下过程以确保密码的兼容性:
        • 降级前,请登录并禁用密码,或将密码更改为先前固件允许的字符长度。
        • 执行固件降级;根据需要启用密码。
    • 使用Designer软件:
      • 使用舒尔Designer软件将多个具有不同固定级别的设备应用于某个位置时,这些设备的位置密码必须遵循原固件的长度和字符集限制。建议将该位置的所有设备更新为最新固件,以使用防护级别更高的密码。
  • 漏洞修复

已知问题

  • AES67支持仅在UltimoX硬件上可用
    • 2017年7月前制造的MXA310设备与AES67兼容
  • 舒尔网络音频加密不向后兼容;所有设备都必须使用4.1版固件才能应用此功能
  • 如注册、取消注册,或更改Dante Domain设置并选择“清除配置”,则设备可能会无限期静音其音频输出。解决方案:执行此操作后,重新启动设备,以避免出现可能的错误操作
  • 2.X版本更新到4.1.37版本后,通道均衡器设置将恢复为默认设置。
  • 在Mac OS上使用Safari导出预设时,会出现文件类型保存不正确的情况,必须将其重命名为.json才能导入。
  • 使用SUU在MXA 4.1和早期版本之间进行升级或降级后,尝试加载设备的网页时,浏览器可能停留在“正在加载”状态且进度条不断移动。如果在一小时内执行两次升级或降级,通常会出现上述情况。若要更正此问题,请按住Shift键,并在浏览器中单击“刷新”按钮(或按Ctrl + Shift + R [Win] / Ctrl + F5 [Win] / Cmd + Shift + R [Mac];请注意键盘快捷键无法在Safari上使用)。
  • 使用<GET 0 ALL>时,静音控制功能命令字符串响应不正确
    • 使用 < GET MUTE_CONTROL_FUNC >时,响应如文档所示。
    • 使用 < GET 0 ALL >时,响应映射应如下表所示:
< GET 0 ALL > ResponseActual MUTE_CONTROL_FUNC
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC >LOCAL
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL >LOGIC
< REP MUTE_BUTTON OFF >DISABLED

说明

  • 用户指南
  • 演示Web UI
  • 命令字符串
  • MXA310版本4.1.37与运行4.1.37及更低版本的MXA310设备兼容,但建议将所有同时使用的设备更新为相同的固件版本
  • 要使用Dante Controller操作MXA310版本4.1.37,请参考以下最低版本:v3.10.2.4(Windows)和v3.10.2.3(Mac OS X)
  • 要使用舒尔软件或其它舒尔网络系统操作MXA310版本4.1.37,请参考以下支持的最低版本列表:
    • 舒尔 Designer 版本 4.1
    • 舒尔 SystemOn 版本 3.2
    • ANI22 版本 4.1.39
    • ANI4IN 版本 4.1.39
    • ANI4OUT 版本 4.1.39
    • ANIUSB-MATRIX 版本 4.1.39
    • MXA910 版本 4.1.41
    • Microflex Wireless 版本 8.0.3
    • P300 IntelliMix® Audio Conferencing Processor 版本 4.1.11
    • SCM820 版本 1.3.3
    • Shure Update Utility 版本 2.4.6
    • Shure Web Device Discovery 版本 1.2.5
3.1.6
2019年6月27日

Recommendation

Update all Audio Network Interfaces in a configuration to the newest firmware versions.

Improvement

  • Fix for web server performance issues

Known Issues

  • After updating from version 2.X to 3.1.6, Channel EQ settings return to their default settings.
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 3.1 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).
  • The Mute Control Function command string response is incorrect when using <GET 0 ALL>
    • When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
    • When using < GET 0 ALL >, the response should be mapped as follows:
< GET 0 ALL > ResponseActual MUTE_CONTROL_FUNC
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC >LOCAL
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL >LOGIC
< REP MUTE_BUTTON OFF >DISABLED

Notes

  • User Guide
  • New Demo Web UI
  • Command Strings
  • MXA310 version 3.1.6 is compatible with MXA310 devices running version 3.1.6 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA310 version 3.1.6 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 3.1.6 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 3.2
    • Shure SystemOn 3.2
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • ANIUSB-MATRIX 3.1.6
    • MXA910 4.0.12
    • Microflex Wireless 6.0.3
    • P300 IntelliMix® Audio Conferencing Processor 3.1.6
    • ULXD4D/4Q 2.3.34
    • SCM820 1.3.3
    • Shure Update Utility 2.4.4
    • Shure Web Device Discovery 1.2.5
3.1.5
2019年1月11日

Recommendation

Update all MXA310 devices in a configuration to the same firmware version.

Improvements

Known Issues

  • After updating from version 2.X to 3.1.5, Channel EQ settings return to their default settings.
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 3.1 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).
  • The Mute Control Function command string response is incorrect when using
    • When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
    • When using < GET 0 ALL >, the response should be mapped as follows:

< GET 0 ALL > Response

Actual MUTE_CONTROL_FUNC

< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC >

LOCAL

< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL >

LOGIC

< REP MUTE_BUTTON OFF >

DISABLED

Notes

  • User Guide
  • New Demo Web UI
  • Command Strings
  • MXA310 version 3.1.5 is compatible with MXA310 devices running version 3.1.5 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA310 version 3.1.5 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 3.1.5 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • ANIUSB-MATRIX 3.1.5
    • MXA910 3.1.5
    • Microflex Wireless 5.2.2
    • P300 IntelliMix® Audio Conferencing Processor 2.1.6
    • ULXD4D/4Q 2.2.24
    • SCM820 1.3.3
    • Shure Update Utility 2.4.2
    • Shure Web Device Discovery 1.2.5
3.0.24
2018年6月20日

Recommendation

Update all MXA310 devices in a configuration to the same firmware version.

Improvements

  • DSP
    • Per-Channel PEQ: Adds PEQ to all channels in MXA310
    • Send to Mix: Assign selected channels to direct out only or direct out and Automix
    • Pre- and Post-Automix Fader
    • Pre- and Post-Automix Mute
    • Automix Gain Meters
  • Hardware Light Ring
    • More color options (now 17 total)
    • More brightness levels (now 6 total, including off)
  • New command strings
  • Bug fixes
    • Devices lock up due to TPCI connection issues
    • Users access GUI without completing password recovery

Known Issues

  • After updating from version 2.X to 3.0.24, Channel EQ settings return to their default settings.
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported

Notes

  • User Guide
  • Command strings
  • MXA310 version 3.0.24 is compatible with MXA310 devices running version 3.0.24 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA310 version 3.0.24 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 3.0.24 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • ANIUSB-MATRIX 2.0.19
    • MXA910 3.0.24
    • Microflex Wireless 5.2.2
    • P300 IntelliMix® Audio Conferencing Processor 2.1.6
    • ULXD4D/4Q 2.2.24
    • SCM820 1.3.3
    • Shure Update Utility 2.4.2
    • Shure Web Device Discovery 1.2
2.0.19
2017年12月18日

Improvement

  • Reduces the loading time over VPN for the web-based graphical user interface (GUI)

Known Issues

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • If Channel 1 is removed using the Add/Remove Channel feature and Channel 2, 3, or 4 is left as a single channel, then audio will not pass through the Automix Out channel. Channel 1 is the only channel that passes audio through the Automix Out channel.

Notes

  • User Guide
  • Command Strings
  • MXA310 version 2.0.19 is compatible with MXA310 devices running version 2.0.19 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA310 version 2.0.19 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 2.0.19 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • ANIUSB-MATRIX 2.0.19
    • MXA910 2.0.19
    • Microflex Wireless 5.1.26
    • ULXD4D/4Q 2.1.16
    • SCM820 1.3.3
    • Shure Update Utility 2.4.1
    • Shure Web Device Discovery 1.1
2.0.7
2017年6月30日

New Features

  • Audio Encryption support with MXA910, MXA310, ANI4IN, ANI4OUT, ANIUSB-MATRIX, ANI22 and P300-IMX.
  • Packet Bridge
  • PEQ import/export options

Improvements

  • Integrates Audinate's Dante™ Ultimo firmware update, which resolves a rare audio loss issue that can occur when devices are static for longer than 1 month.
  • Configuration
    • "Add/Remove Channel" button added on Coverage tab
  • Presets
    • "Default Settings" added as a preset
    • Name of the active preset displays above the Preset drop-down
    • "Clear Preset" option added to "Save As Preset"
  • Device names can now begin with a number
  • New command strings
  • Fixed an IP configuration issue in manual mode that prevents setting IP address w.x.y.z with subnet mask 255.0.0.0 for class A networks.
  • General bug fixes

Known Issues

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Encryption may become disabled in an extremely rare case after a power cycle of the device; users must re-enable encryption in the UI if this occurs.
  • If Channel 1 is removed using the Add/Remove Channel feature and Channel 2, 3, or 4 is left as a single channel, then audio will not pass through the Automix Out channel. Channel 1 is the only channel that passes audio through the Automix Out channel.

Notes

  • MXA310: User Guide | Command Strings
  • MXA310 version 2.0.7 is compatible with MXA310 devices running version 2.0.7 and below, but it is recommended to update all devices used together to the same firmware version.
  • To operate MXA310 version 2.0.7 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 2.0.7 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 2.0.7
    • ANI4OUT 2.0.8
    • MXA910 2.0.8
    • Microflex Wireless 5.1.23
    • ULXD4D/4Q 2.1.16
    • SCM820 1.3.3
    • Shure Update Utility 2.3.0.18
    • Shure Web Device Discovery 1.1
1.2.6
2016年12月1日

RECOMMENDATION

Update all Microflex® Advance™ microphones and Audio Network Interfaces in a configuration to the same firmware version.

IMPROVEMENTS

  • Push to Dante feature now appends a -d to the Dante Device Name, preventing discovery issues
  • Bug fixes

KNOWN ISSUE

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported

NOTES

  • MXA310 version 1.2.6 is compatible with microphones running version 1.2.6 and below, but it is recommended to update all devices used together to the same firmware version.
  • For operation of MXA310 version 1.2.6 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 1.1.6
    • ANI4OUT 1.1.6
    • MXA910 1.1.3
    • Microflex Wireless 4.0.7
    • ULXD4 1.7.34
    • ULXD4Q 1.7.34
    • SCM820 1.3.3
    • Shure Update Utility 2.2.2
    • Shure Web Device Discovery 1.0.18
1.1.4
2016年7月8日

Initial release

相关联产品

MXA310

MXA310 采用Steerable Coverage™,包含4个独立拾音模式和全新环形拾音模式,可抑制上方的空调声和风扇噪音。直观的用户界面,可以轻松配置预设值、模板和拾音模式。